DHC-E Technical Data

Model
DHC-E 8
DHC-E 10
Phase
1
1
Voltage
V
208
240
208
240
Wattage
kW
5.4
7.2
7.2
9.6
Amperage
A
26
30
35
40
Min. Required circuit breaker size
A
30
40
40
50
Recemmended wire size
AWG COPPER
10
8
8
8
 
Maximum temperature increase
@0.75 GPM
49
65
65
87
above ambient water temp.
@1.00 GPM
37
49
49
65
@1.50 GPM
25
33
33
44
Min. water flow to activate unit
GPM / lmin
0.29 / 1.1
0.29 / 1.1
Pressure loss in unit
PSI / bar
1.46 / 0.1
1.46 / 0.1
Weight
LB / kg
5.9 / 2.7
Nominal water volume
Gal.
0.13 / 0.51
Working pressure
PSI / bar
150 / 10
Tested to pressure
PSI / bar
300 / 20
Water connections
1 / 2" NPT
DHC-E temp rise graph

ETL Listed ISO 9001 Certified ETL Canada Listed
Three Year Limited Warranty

©2007 Stiebel Eltron, Inc. All rights reserved.