Mini™ Tankless Technical Data


Model
Mini™ 3 Mini™ 4 Mini™ 6
Phase
1 1 1 1 1
Voltage
115 - 125 208 220 - 240 208 220 - 240
Wattage
kW 
3.0 2.6 3.5 4.3 5.7
Amperage
25 12.6 15.2 20 24.7
Min. required
circuit breaker size
30 20 20 30 30
Recommended wire size
AWG coppper 
10
12
12
10
10
Min. water flow to activate unit
GPM/Lmin 
0.53 / 2.0 0.53 / 2.0 0.53 / 2.0
Degree of protection
according to IEC 529
IP 24
Min. water resistivity
2795 ohm x in / 1100 ohm x cm
Weight
lbs / KG 
3.44 / 1.56
Dimensions (Height/Width/Depth)
in / (cm)
6.5 (16.5) / 3.25 (8.2) / 7.5 (19.0)
Working pressure
Psi / bar 
150 / 10
Tested to pressure
Psi / bar 
300 / 20
Volume of water in unit
Gal / L 
0.026 / 0.1
Water connections
for 3/8" O.D. flex connector
Mini temp rise graph

ETL Listed ISO 9001 Certified ETL Canada Listed
Three Year Limited Warranty

©2007 Stiebel Eltron, Inc. All rights reserved.


< Back to Mini™ main page